Coded Keypad With Biometrics
AC330 Instruction Manual
Read before installation or use
TopRead Before Installing or Using This Device
This device has been designed for integration into professional access control systems in residential, commercial, or industrial buildings. It must only be installed and handled by qualified technical personnel, in accordance with the manufacturer's specifications. Improper use, unauthorised handling, or incorrect installation may cause serious harm to persons or property, and will void both the warranty and the manufacturer's liability.
Electrical Safety
Before connecting, disconnecting, or intervening with the device, ensure the power supply is completely switched off. Although this product operates at low voltage (e.g. 12–24 VDC), improper handling can cause short circuits, door damage, overheating, or risk of electric shock.
Intended Use and Compatibility
This device is suitable for wooden, metal, or aluminium doors, depending on the model. Certain models are certified for use on fire doors and emergency exits. Always verify the specific certifications and compatibility before installation. Use in environments exposed to water, heavy dust, or aggressive chemical agents is not recommended unless the device is properly certified (e.g. IP65, IP68 etc.).
Maintenance and Use
Do not open, modify, or tamper with the interior of the device. Any unauthorised intervention will automatically void the warranty. Cleaning should be carried out using soft cloths and non-abrasive products. Periodic maintenance by a qualified technician is recommended, particularly in high-usage environments.
Limited Warranty
This product is covered by a commercial warranty against manufacturing defects for the period specified by Openers & Closers. The warranty does not cover normal wear and tear, incorrect installation, tampering, mechanical impacts, or unsuitable environmental conditions. Openers & Closers shall not be held liable for indirect damage, financial loss, or harm resulting from improper or non-compliant use.
Regulations and Compliance
This product complies, where applicable, with relevant regulations in each market (e.g. CE, RoHS, WEEE, UL 294, NFPA-80, EN 14846). Refer to the product labelling and technical documentation to confirm specific certifications.
Disposal and Recycling
This device contains electronic components and must not be disposed of with household waste. It must be taken to an authorised collection point for electrical and electronic equipment (WEEE). The crossed-out wheeled bin symbol indicates this legal requirement. The packaging is recyclable and should be disposed of in accordance with local regulations.
Intellectual Property and Documentation
The content of this manual, as well as the technology integrated into the product, is protected by intellectual and industrial property rights. Its reproduction, distribution, translation, or modification is prohibited without the express authorisation of Openers & Closers.
Dimensions
Top
Installation
Top

Connection Diagram (Option 1)
Top- U1Power supply
- U2AC330 Keypad
- U3Push button (TP Series)
- U4Electric/Electronic Strike Option (Series 1,3,5,8 and 9)

Connection Diagram (Option 2)
Top- U1Power supply
- U2AC330 Keypad
- U3Push button (TP Series)
- U4Electromechanical Lock (CE Series)

Connection Diagram (Option 3)
Top- U1Power supply
- U2AC330 Keypad
- U3Push button (TP Series)
- U4Electromagnetic Strike Option (ME, MEX Series)

User Guide
TopLight and Sound Indications
| State | Red Light | Green Light | Speaker |
|---|---|---|---|
| Standby | Active | - | - |
| Key pressed | - | - | 1 beep |
| Correct operation | - | Active | 1 beep |
| Failed operation | - | - | 3 beep |
| In programming mode | Blinking | - | 1 beep |
| Door opening | - | Active | 1 beep |
Programming Guide: User Configuration
Top| Action | Command |
|---|---|
| Enter programming mode: | [*] [Master Code] [#] Note: the default master code is 999999 |
| Exit programming mode: | [*] |
Note that to perform the following programming, the master user (programming mode) must log in.
| Action | Command |
|---|---|
| Change the master code: | [00] [New Code] [#] [New Code] [#] Note: The master code must be 6 digits. |
Work Mode Selection
| Action | Command |
|---|---|
| Select a work mode: Without possibility to combine method options | [31] [0] [#] Door opening prohibited |
| [31] [1] [#] Code only entry | |
| [31] [2] [#] Card only entry | |
| [31] [3] [#] Entry with card + code or fingerprint + code | |
| [31] [4] [#] Entry with card or fingerprint or code | |
| [31] [5] [#] Fingerprint only entry | |
| [31] [6] [#] Entry with fingerprint + card | |
| [31] [7] [#] Entry with multi-fingerprint / multi-card | |
| EXAMPLE: [*]999999[#][31][0][#] Note: The default value is 4 | |
| [32] [1] [#] Open the door with a user card or user fingerprint | |
| [32] [2-10] [#] Open the door with 2-10 user cards or user fingerprints | |
| EXAMPLE: [*]999999[#][32][1][#] Note: The default value is 1 |
Add Users
| Action | Command |
|---|---|
| Add card users or fingerprint users continuously: | [11] Card reading and/or record a fingerprint twice [#]... [*] |
| Add card users by card number | [11] Enter the 8 or 10 digit card number [#]... [*] |
| Add card or fingerprint users by specific identification number | [11] Enter the [ID] number [#] card reading or enter a fingerprint twice [#]... [*] |
| Add card users by specific identification number and card number | [11] Enter the [ID] number [#] press the 8 or 10 digit card number [#]... [*] |
| Add an independent user code by specific identification number | [11] Enter the [ID] number [#] press the code [#]... [*] |
| Pair fingerprints with a card (maximum 2 fingerprints) | [12] Card reading, record the first fingerprint twice, record the second fingerprint twice [#]... [*] |
| Note: “...” means to repeat the previous operation, press the [*] key to exit. | EXAMPLE: [*]999999[#][11][ID][#]... [*] |
Delete Users
| Action | Command |
|---|---|
| Delete card users by reading the card / Delete fingerprint users by entering the fingerprint | [21] Card reading or enter fingerprint once [#]... [*] |
| Delete card users by card number | [21] Press the 8 or 10 digit card number [#]... [*] |
| Delete users by identification number | [21] Press the [ID] number [#]... [*] |
| Note: “...” means to repeat the previous operation, press the [*] key to exit. | EXAMPLE: [*]999999[#][21][ID][#]... [*] |
| Delete all users | [20] 0000[#] |
Programming Guide: Door Configuration
Top| Action | Command |
|---|---|
| Enter programming mode: | [*] [Master Code] [#] Note: the default master code is 999999 |
| Exit programming mode: | [*] |
Note that to carry out the following programming, the master user (programming mode) must log in.
| Action | Command |
|---|---|
| Door opening time range: 0-300s, 0 equals 50ms: | [41] [0-300] [#] Note: The default value is 5 |
| Alarm time set to 0s means no alarm: | [42] [0] [#] |
| Alarm time range: 1-99 min. | [42] [1-99] [#] |
| Normal work mode | [61] [0] [#] |
| The external alarm and built-in buzzer will operate if more than 5 incorrect operations are performed | [61] [1] [#] |
| The device will lock for 10 minutes if more than 5 incorrect operations are performed | [61] [2] [#] |
| Note: The default value is 0 | EXAMPLE: [*]999999[#][42][0][#] |
| Disable light indicator | [62] [0] [#] |
| Enable light indicator | [62] [01] [#] |
| Disable keypad backlight | [63] [0] [#] |
| Enable keypad backlight | [63] [01] [#] |
| Keypad backlight time: 2-99 seconds | [63] [2-99] [#] |
| Disable buzzer | [64] [0] [#] |
| Enable buzzer | [64] [01] [#] |
| Note: The default value is 1 | EXAMPLE: [*]999999[#][63][0][#] |
User Operation: Change User Code
TopChange User Code by Card
| Press * | Read card | Old code # | New code # | New code # |
|---|
Change User Code by Fingerprint
| Press * | Enter fingerprint | Old code # | New code # | New code # |
|---|
Change User Code by Identification Number
| Press * | ID Number | # | New code # | New code # |
|---|
Other Operations
TopReset to Factory Settings
- Users can reset the factory default settings when the administrator code is forgotten, or the default configuration has been modified, as follows:
- Method 1: Turn off the device, turn it on, press the # key when the indicator light turns orange, listen for 2 beeps, release the # key; the administrator code has been reset to 999999, and the factory default settings have been successfully restored.
- Method 2: Turn off, press the exit button continuously, turn it on, listen for 2 beeps; the administrator code has been reset to 999999, and the factory default settings are correct.
- Note: Registered user data will not be erased when resetting to factory settings.
Deactivate Alarm
| Read admin card or Read user card or Enter admin code | # |
|---|
Contact Technical Support
Can't find what you're looking for? Our technical support team can help.
Get Help